IRC §R302.5.1

What kind of door is required between an attached garage and the house?

IRC §R302.5.1model code

A solid wood or solid/honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door - and it cannot open into a sleeping room (IRC R302.5.1).

A door connecting an attached garage to the residence must be one of three types: a solid wood door not less than 1-3/8 inches thick, a solid or honeycomb-core steel door not less than 1-3/8 inches thick, or a 20-minute fire-rated door.

Openings from the garage directly into a room used for sleeping purposes are not permitted.

Many jurisdictions (and newer code editions) also require this door to be self-closing and self-latching, so check your local amendments.